List Price: CAD 949.02 CAD 474.51 -50%
OFUC8R-N Fire Alarm Control Panel is a microprocessor based unit designed for small to medium commercial, residential, multifamily, institutional and industrial occupancies. Fully configurable using DIP switches, it enables the user to configure the system to meet
their specific requirements.
Datasheet Add to cart
• 8 Class B (Style B) 4 Class A (Style D) Initiating Circuits 4 Class
A (Style D) circuits.
• Predefined Initiating Circuits can be configured as Waterflow or
Latching/Non- Latching Supervisory
• Selectable Alarm Verification on Initiating Circuits
• Zone Disconnect Switches
• 5 Amp Power Supply
• 4 Class A/B (Style Z/Y) Indicating Circuits (1.7 Amps max. per
circuit.)
• Audibles may be configured as Steady, Temporal Code, California
Code, or March Time
• Auto Signal Silence
• Auxiliary relay contacts for Common Alarm, Common Trouble,
and Common Supervisory.
• Built-in RS-485 Interface for RA8F Multiplexed Remote
Annunciators (Up to 3 Annunciators)
• Built-in Walk Test operation
• Output for 4-wire resettable regulated smoke power.
• Easy configuration via DIP switches
The OFUC8R-N is a OFUC4R-E with the ZA42 expansion card factory installed. In addition, the preassembled kit contains a UDACT-9100 for digital communication.The OFUC8R-N comes standard with 8 Class B (Style B) Initiating Circuits which may be configured as 4 Class A (Style D) circuits. In addition, it comes equipped with 4 Class A/B (Style Z/Y) Indicating circuits which are each rated at 1.7 amps. The panel also includes a 5 Amp Power Supply which powers the system and supplies a 4-wire resettable regulated smoke power supply of 24 VDC 100mA maximum.
The OFUC8R-N utilizes a simple DIP switch configuration for programming initiating and indicating circuits as well as the enabling and disabling of system functions such as Signal Silence, Fire Drill and Auxiliary Disconnect. Some predefined initiating circuits can optionally be configured Waterflow or Latching/Non-Latching Supervisory. In addition, the PFC-5008 allows for Alarm Verification on the initiating circuits. The indicating circuits may be configured as Silenceable orNon-Silenceable with the audibles configured for Steady, March-Time, Temporal Code, or California Code. Sync module required for strobe synchronization.
The OFUC8R-N is equipped with auxiliary relay contacts for Common Alarm, Trouble and Supervisory. If no Supervisory circuits are enabled, the Supervisory relay becomes a second Alarm relay. The cabinet is available in a beige color for the Canadian market and a red exterior for the U.S. and International markets.
Specifications
Charging Capability: 4 - 24 AH Batteries
Space is provided for up to 12 AH batteries.
24 AH Batteries require a separate battery cabinet.
Dimensions
14 7/8"H x 14 1/2"W x 5"D
Electrical Specs
AC Main: 2.0 Amps @ 120 VAC 60 HZ
1.0 Amp @ 240 VAC 50 HZ
Battery: 155 mA Standby (PFC-5008)
340 mA Alarm (PFC-5008)
200 mA Standby (PFC-5008 with AFCT)
460 mA Alarm (PFC-5008 with AFCT)